Home ProductsTemperature Humidity Chamber

Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy

Certification
Good quality Salt Spray Test Chamber for sales
Good quality Salt Spray Test Chamber for sales
Customer Reviews
Thanks a lot for the professional service of Q1-Test team, we are happy to have the temperature test chamber, and it works well until now.

—— Tonny Cruise

Salt spray test chamber was installed last week according to your guide, it is working well now, thank you. we will recommend it to my friends.

—— Robert Antonio

Our 1000L temperature test chamber QTH-1000C works very well after installed and set by Q1-test service guy. Our staff can operate it fluently. Thanks

—— Juan Smith

I'm Online Chat Now

Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy

China Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy supplier
Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy supplier Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy supplier Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy supplier Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy supplier

Large Image :  Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy

Product Details:

Place of Origin: DONGGUAN
Brand Name: Q1-TEST
Certification: CE,ISO,SGS
Model Number: QTS-80-3

Payment & Shipping Terms:

Minimum Order Quantity: 1 SET
Price: Negotiable
Packaging Details: Plywood box
Delivery Time: 45 work days
Payment Terms: T/T
Supply Ability: 20 set per month
Detailed Product Description
Power: AC380v 50Hz/60Hz Controller: Programmable LCD Touch Screen
Warranty: 1 Year Refrigerant: Environmental Friendly R23/R404a
System: P.I.D+S.S.R+Micro-coemmputer Balanced Temperature Control Temperature Range: -40~150C/-60~150C
High Light:

thermal shock chamber

,

shock test machine

Cold , heat and ambient test, Thermal Shock Test Chamber with high accuracy

 

Description:

 

Q1-Test thermal shock test chamber is used to test products in alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence, click www.q1-test.com for details.

Air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer

 

Features:

 

1. Automatically setting of pro-cooled and pre-heated air.

2.Testing samples don’t move, cable port is available for power on testing.

3.Powerful interactive touch screen controller, easy operation and setting

4.High accurate temperature recovery with PID auto tuning

5.Auto defrost function

 

Testing Standards:

 

MIL-STD-883E Method 1011.9 Thermal Shock

MIL-STD-202G Method 107G thermal Shock

JIS C 0025 Change of temperature

IEC 61300-2-47 Tests-Thermal Shocks

JESD22-A104C Temperature cycling

GB/T 2423.22-2012 Test N: Change of temperature

 

Model Selection:

 

Model TEMP. RANGE

interior dimensions

(W ×H × D)cm

Exterior dimensions

(W ×H × D)cm

QTS-80-3 -40~150℃ 50*40*40 145*195*155
QTS-150-3 60*50*50 155*205*165
QTS-225-3 70*50*60 175*205*185
QTT-80-3 -65~150℃ 50*40*40 145*195*155
QTT-150-3 60*50*50 155*205*165
QTT-225-3 70*50*60 175*205*185

Note:
Two-zone are the same size as the three; accept the above standard specifications,support customer purchase non-standard machine.

 

 

Specifications:

 

Structure Pre-cooling Zone, Pre-heating Zone, Testing Zone (Selectable 2-Zone or 3-Zone Test for stationary object test)
Damper Device Forced Air Damper
Interior Material SUS#304 Stainless Steel
Exterior Material stainless steel with environmentally baking paint
Testing Shelves Stainless Steel Plate
Refrigeration Cascade Refrigeration System
Cooling Method Water/Air Cooling
Ambient Temperature 5℃~30℃
Pre-heating Temperature 80℃~200℃
Pre-cooling Temperature -40℃ (-60℃/-75℃)~-10℃
High Temp. Shocking 60℃~150℃
Low Temp. Shocking

A=―35℃~0℃

B=―55℃~10℃

C=―65℃~10℃

Temp. Uniformity Less than ±2℃
Transition time <10 seconds
High Temp. Recovery time RT℃~150℃/5min
Low Temp. Recovery time RT℃~-75℃/5min
Pre-heating Time 35min
Pre-cooling Time 85min
Controller Powerful interactive LCD touch screen controller
Setting Range

Temperature: -200℃~300℃

Time: 0H1m~9999H59m

Cycle: 1~9999cycle

Resolution

Temperature: 0.01℃

Time: 1min

Control Method PID+SSR
Power supply AC380V/50Hz/3P
Accessories

Viewing Window, Cable Port, Chamber Illumination,

LCD touch screen controller, Power cable

Security System Overheat Protector, Compressor overload protector, Controller protector, Motor overload protector

 

Test conditions:

 

1. Ambient temperature of +23℃ and a cooling water temperature of +25℃

2. During pre-heating, prevention for temperature heat-up may be worked

3. Performance shown above conforms to IEC61300-2-47

4. Temperature heat-up/pull-down time is applicable only during independent chamber operation

Cold , Heat And Ambient Thermal Shock Test Chamber With High Accuracy

Contact Details
DongGuan Q1-Test Equipment Co., Ltd.

Contact Person: Mr. Andy DAI

Tel: +86-13450058229

Fax: 86-769-2278-4276

Send your inquiry directly to us (0 / 3000)